LTE65ES-S2-1

Environment Specification:

  • Operating Temperature:0-40℃
  • Storage Temperature:-40 to 85 ℃
  • Storage Humidity: 5% to 95% RH

Protection Specification:

  • Over Voltage Protection: Latch Off
  • Over Load protection: Hiccup/Auto-Recovery
  • Short Circuit Protection: Hiccup/Auto-Recovery

Safety and EMC Approval:

  • ITE: UL. cUL. TUV/GS. BSMI. CE. CB

Mechanical Specification:

  • Dimensions: 123.12*54.22*35.00(mm)
  • AC INLET: C14 (3pins)

Mechanical Drawing:


 
12V 5A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-S3-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:


Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
15V 4A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-SW-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:


Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
19V 3.42A 65W >85%;>86% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-S4-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
24V 2.7A 65W >86%;>87% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-SR-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
32V 2.04A 65W >87%;>88% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-S5-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:


Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
48V 1.35A 65W >88%;>89% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-S7-1

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C14 (3pins)
56V 1.16A 65W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type

LTE65ES-S2-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:


Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
12V 5A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-S3-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
15V 4A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-SW-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
19V 3.42A 65W >85%;>86% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-S4-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
24V 2.7A 65W >86%;>87% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-SR-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
32V 2.04A 65W >87%;>88% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-S5-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
48V 1.35A 65W >88%;>89% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-S7-2

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C6 (3pins)
56V 1.16A 65W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type

LTE65ES-S2-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
12V 5A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-S3-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
15V 4A 60W >85% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-SW-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
19V 3.42A 65W >85%;>86% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-S4-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
24V 2.7A 65W >86%;>87% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-SR-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
32V 2.04A 65W >87%;>88% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-S5-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:


Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
48V 1.35A 65W >88%;>89% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type

LTE65ES-S7-3

Environment Specification:
Operating Temperature:0-40℃
Storage Temperature:-40 to 85 ℃
Storage Humidity: 5% to 95% RH
 
Protection Specification:
Over Voltage Protection: Latch off
Over Load Protection: Hiccup/Auto-Recovery
Short Circuit Protection: Hiccup/Auto-Recovery
 
Safety and EMC Approval:
ITE: UL. cUL. TUV/GS. BSMI. CE. CB
Mechanical Drawing:

 

Mechanical Specification:
Dimensions: 123.12*54.22*35.00(mm)
AC INLET: C8 (2pins)
56V 1.16A 65W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type