Products External Switching Power Supply Switching Power Supply (Level VI) 50W Output Voltage --Select-- 12V 15V 19V 24V 48V 56V Output Current --Select-- 4.17A 3.34A 2.64A 2.09A 1.05A 0.9A AC PLUG TYPE --Select-- IEC-320, C14 Desk Type IEC-320, C6 Desk Type IEC-320, C8 Desk Type Search Clear Result Pages: [1] Results 1 - 18 of 18 Please Click products below, and click Add to Inquiry List for inquiry. LTE50ES-S2-1 Environment Specification: Operating Temperature:0-40℃ Storage Temperature:-40 to 85 ℃ Storage Humidity: 5% to 95% RH Protection Specification: Over Voltage Protection: Latch Off Over Load protection: Hiccup/Auto-Recovery Short Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval: ITE: UL. cUL. BSMI. FCC. LPS. CB Mechanical Specification: Dimensions: 72.57*48.97*30(mm) AC INLET: C14 (3pins) Mechanical Drawing: PDF 12V 4.17A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-S3-1 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity:5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C14 (3pins) PDF 15V 3.34A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-SW-1 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity:5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C14 (3pins) PDF 19V 2.64A 50W >86% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-S4-1 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity:5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C14 (3pins) PDF 24V 2.09A 50W >87% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-S5-1 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity:5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C14 (3pins) PDF 48V 1.05A 50W >88% : >89% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-S7-1 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity:5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C14 (3pins) PDF 56V 0.9A 50W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C14 Desk Type LTE50ES-S2-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 12V 4.17A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-S3-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 15V 3.34A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-SW-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 19V 2.64A 50W >86% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-S4-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 24V 2.09A 50W >87% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-S5-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 48V 1.05A 50W >88% : >89% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-S7-2 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions: 117.6*50.2*31.6(mm)AC INLET: C6 (3pins) PDF 56V 0.9A 50W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C6 Desk Type LTE50ES-S2-3 Environment Specification: Operating Temperature:0-40℃ Storage Temperature:-40 to 85℃ Storage Humidity: 5% to 95% RH Protection Specification: Over Voltage Protection: Latch Off Over Load protection: Hiccup/Auto-Recovery Short Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval: ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification: Dimensions:117.6*50.2*31.6(mm) AC INLET: C8 (2pins) PDF 12V 4.17A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type LTE50ES-S3-3 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions:117.6*50.2*31.6(mm)AC INLET: C8 (2pins) PDF 15V 3.34A 50W >84% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type LTE50ES-SW-3 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions:117.6*50.2*31.6(mm)AC INLET: C8 (2pins) PDF 19V 2.64A 50W >86% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type LTE50ES-S4-3 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions:117.6*50.2*31.6(mm)AC INLET: C8 (2pins) PDF 24V 2.09A 50W >87% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type LTE50ES-S5-3 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions:117.6*50.2*31.6(mm)AC INLET: C8 (2pins) PDF 48V 1.05A 50W >88% : >89% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type LTE50ES-S7-3 Environment Specification:Operating Temperature:0-40℃Storage Temperature:-40 to 85℃Storage Humidity: 5% to 95% RH Protection Specification:Over Voltage Protection: Latch OffOver Load protection: Hiccup/Auto-RecoveryShort Circuit Protection: Hiccup/Auto-Recovery Safety and EMC Approval:ITE: UL. cUL. TUV. BSMI. FCC .CE. CB Mechanical Drawing: Mechanical Specification:Dimensions:117.6*50.2*31.6(mm)AC INLET: C8 (2pins) PDF 56V 0.9A 50W >89% DoE VI /ErP CoC V5. Tier II IEC-320, C8 Desk Type Add to Inquiry List Review Inquiry List Back