Result Pages: [1] Results 1 - 13 of 13
Please Click products below, and click Add to Inquiry List for inquiry.

SA142B-12U

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
ErP Requirement: Stage II
MEPS: Level V
Energy Star: EPS 2.0
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 5ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

12V

3.5A

42W

80%

ErP I,CEC V, EPS 2.0

IEC - 320, C8

SA145A-1240U-6(36W)

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧10 mSec
Standby Power: ≦1 Watt
EMI: Complies with EMI directives
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 6ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 
12V 3.0A 36W 75% IEC-320, C8

SA145A-1240V-6(36W)

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧10 mSec
Standby Power: ≦1 Watt
EMI: Complies with EMI directives
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 6ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 
12V 3.0A 36W 75% IEC-320, C14

SA142B-12V

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 1800 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
ErP Requirement: Stage II
MEPS: Level V
Energy Star: EPS 2.0 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 5ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

12V

3.5A

42W

80%

ErP II,CEC V, EPS 2.0

IEC - 320, C14

SA145A-1240U-6(48W)

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧10 mSec
Standby Power: ≦1 Watt
EMI: Complies with EMI directives
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 6ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 
12V 4.0A 48W 75% IEC-320, C8

SA145A-1240V-6(48W)

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8,  2PIN
Output
Line Regulation ±2%
Load Regulation ±5%
Protections OCP, OVP & Short circuit
Ripple & Noise ≦120mVp-p
 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧10 mSec
Standby Power: ≦1 Watt
EMI: Complies with EMI directives
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 255, ±5 g (36W)
             275, ±5 g (48W)
DC Cord 6ft
LED Indicator Optional

Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard))
Safety ITE : UL, CSA, TUV/GS, CB,
CE, PSE
 
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 
12V 4.0A 48W 75% IEC-320, C14

SA150B-12U

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C8, - 2PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦100MvP-P (for 9V model)
≦1%Vo (for 12V~33V models)

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
ErP Requirement:Stage I
MEPS: Level IV
Energy Star: EPS 2.0
 
Mechanical
Case Size: 122L x 60W x 34H mm
Case Material: Black, 94V-1 or equivalent
Weight: 330 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 100,000 hrs (by MIL-217 Standard)
Safety TE : UL, CSA, TUV/GS, CE,
CB, PSE, CCC
AV : UL, CUL, TUV/GS, CE,
CB, PSE
Others
Package 30 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

12V

4.0A

48W

75%

ErP I, CEC IV, EPS 2.0

IEC - 320, C8

SA150B-12V

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C14, - 3PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦1%Vo

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 1800 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement:
Efficiency Level V
ErP Requirement: Stage I
MEPS: Level IV
Energy Star: EPS 2.0 
Mechanical
Case Size: 110L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 280 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard)
Safety Medical : CUS, CSA, CB,
Nemko, CE
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

12V

4.0A

48W

75%

ErP I,CEC IV, EPS 2.0

IEC - 320, C14

SA150B-15U

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C8, - 2PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦100MvP-P (for 9V model)
≦1%Vo (for 12V~33V models)

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
ErP Requirement: Stage I
MEPS: Level IV
Energy Star:EPS 2.0 
Mechanical
Case Size: 122L x 60W x 34H mm
Case Material: Black, 94V-1 or equivalent
Weight: 330 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 100,000 hrs (by MIL-217 Standard)
Safety TE : UL, CSA, TUV/GS, CE,
CB, PSE, CCC
AV : UL, CUL, TUV/GS, CE,
CB, PSE
Others
Package 30 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

15V

3.3A

49.5W

80%

ErP I, CEC IV, EPS 2.0

IEC - 320, C8

SA150B-15V

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C14, - 3PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦1%Vo

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 1800 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement:
Efficiency Level V
ErP Requirement: Stage I
MEPS: Level IV
Energy Star: EPS 2.0 
Mechanical
Case Size: 110L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 280 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard)
Safety Medical : CUS, CSA, CB,
Nemko, CE
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

15V

3.3A

49.5W

80%

ErP I,CEC IV, EPS2.0

IEC - 320, C14

SA150B-24U

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C8, - 2PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦100MvP-P (for 9V model)
≦1%Vo (for 12V~33V models)

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
ErP Requirement: Stage II
MEPS: Level V
Energy Star: EPS 2.0 
Mechanical
Case Size: 122L x 60W x 34H mm
Case Material: Black, 94V-1 or equivalent
Weight: 330 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 100,000 hrs (by MIL-217 Standard)
Safety TE : UL, CSA, TUV/GS, CE,
CB, PSE, CCC
AV : UL, CUL, TUV/GS, CE,
CB, PSE
Others
Package 30 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

24V

2.1A

50.4W

80%

ErP II, CEC V, EPS 2.0

IEC - 320, C8

SA150B-24V

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1500mA at 100-240VAC
Configuration IEC-320, C14, - 3PIN
Output
Line Regulation ≦±2%
Load Regulation ≦ ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage ≦1%Vo

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 1800 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.5Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement:
Efficiency Level IV
ErP Requirement: Stage II
MEPS: Level V
Energy Star: EPS 2.0
 
Mechanical
Case Size: 110L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 280 ±5 g
DC Cord 5ft
LED Indicator Optional


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 50,000 hrs (by MIL-217 Standard)
Safety Medical : CUS, CSA, CB,
Nemko, CE
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 

24V

2.1A

50.4W

80%

ErPII,CEC V, EPS 2.0

IEC - 320, C14

SA145A-2421U-6

 
Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 1200mA at 100-240VAC
Configuration IEC-320, C8, - 2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & Short circuit
Ripple Voltage 240mVp-p (max)

 
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
240VAC/50Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.75Watt
Consumption
EMI: Complies with EMI directives
 
Mechanical
Case Size: 111L x 50W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 275 ±5 g
DC Cord 6ft



Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Operating Humidity 20% - 80% (Non-condensing)
   
Reliability
MTBF 100,000 hrs (by MIL-217 Standard)
Safety ITE: UL, CUL, TUV/GS, CB
CE, PSE, CCC, LPS
Others
Package 60 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year 
24V
2.1A
50.4W
78%
 
IEC-320, C8
Desk Type
Add to Inquiry List
Review Inquiry List
Back