Result Pages: [1] Results 1 - 19 of 19
Please Click products below, and click Add to Inquiry List for inquiry.

SA104A-05

Input

  • Rated Voltage: 100 - 240 VAC
  • Max. Voltage: 90 - 264 VAC
  • Line Frequency: 47 - 63 Hz
  • Current: 250mA at 100-240VAC
  • Configuration: UL-2PIN

Output

  • Line Regulation: Less than ±2%
  • Load Regulation: Less than ±5%
  • Protections: OCP, OVP & SCP
  • Ripple & Noise: ≦150mVp-p

Electrical

  • Topology: Switching Mode
  • Hi-Pot: 3000 Vac/1sec @ 5mA (primary - secondary)
  • Leakage Current: ≦0.25mA,at 264VAC/50Hz
  • Hold Up Time: ≧8 mSec
  • Standby Power: ≦0.3 Watt
  • EMI: Complies with EMI directives
  • Consumption
  • EMI: Complies with EMI directives
  • CEC Requirement: Efficiency Level:IV
  • Energy Star Requirement:EPS2.0(Efficiency Level: IV)

Mechanical

  • Case Size: 50L x 25W x 41H mm
  • Case Material: Black, 94V-1 or equivalent
  • Weight: 75 ±5 g
  • DC Cord: 4.92ft

Environment

  • Operating Temp.: 0℃- 40℃
  • Storage Temp.: -20℃- 80℃
  • Humidity: 10% - 90% (Non-condensing)
  • RoHS & WEEE: Standard

Reliability

  • MTBF: 50,000 hrs (by MIL-217 Standard)
  • Safety ITE: UL, cUL

Others

  • Package: 100 pcs/box
  • Min. Order: 1K pcs/lot
  • Warranty: 1 year

5V

0.8A

4W

63%

CEC IV,
ENERGY STAR 2.0

UL
WALL TYPE

SA104A-05G

Input

  • Rated Voltage: 100 - 240 VAC
  • Max. Voltage: 90 - 264 VAC
  • Line Frequency: 47 - 63 Hz
  • Current: 250mA at 100-240VAC
  • Configuration: Europe-2PIN

Output

  • Line Regulation: Less than ±2%
  • Load Regulation: Less than ±5%
  • Protections: OCP, OVP & SCP
  • Ripple & Noise: ≦200mVp-p

Electrical

  • Topology: Switching Mode
  • Hi-Pot: 3000 Vac/1sec @ 5mA (primary - secondary)
  • Leakage Current: ≦0.25mA,at 264VAC/50Hz
  • Hold Up Time: ≧8 mSec
  • Standby Power: ≦0.3 Watt
  • Consumption
  • EMI: Complies with EMI directives
  • CEC Requirement: Efficiency Level:IV
  • Energy Star Requirement: EPS2.0(Efficiency Level: IV)

Mechanical

  • Case Size: 50L x 25W x 41H mm
  • Case Material: Black, 94V-1 or equivalent
  • Weight: 80 ±5 g
  • DC Cord: 4.92ft

Environment

  • Operating Temp.: 0℃- 40℃
  • Storage Temp.: -20℃- 80℃
  • Humidity: 10% - 90% (Non-condensing)
  • RoHS & WEEE: Standard

Reliability

  • MTBF: 50,000 hrs (by MIL-217 Standard)
  • Safety ITE: UL, cUL

Others

  • Package: 100 pcs/box
  • Min. Order: 1K pcs/lot
  • Warranty: 1 year

5V

0.8A

4W

63%

CEC IV,
ENERGY STAR 2.0

EUROPE
WALL TYPE

SA106C-05GS

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration EUROPE-2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
ErP Requirement: Stage 2
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 5ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: TUV/GS, CB, CE
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year
5V
1.2A
6W
65%
ErP II, CEC V

Europe
Wall
Type

SA106C-05G

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration Australia -2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
ErP Requirement: Stage 2
Mechanical
Case Size: 64L x 45W x 28H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 5ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: TUV/GS, CB, CE
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year
5V 1.2A 6W 65%

ErP II, CEC IV

Europe.straight
Wall
Type

SA106C-05S

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration UL-2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
Effective January 1, 2008
(Efficiency Level: IV)
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 6ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: UL, CUL
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year
5V
1.2A
6W
65%
CEC IV

UL
Wall
Type

SA106C-05

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration UL-2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
Consumption
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
Effective January 1, 2008
(Efficiency Level: IV)
Mechanical
Case Size: 65L x 44W x 28H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 6ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: UL, CUL
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year
5V
1.2A
6W
65%
CEC IV

UL.Straight
Wall Type

SA106C-05BS

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration British -2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
ErP Requirement: Stage 2
(9V & 12V ErP I only)
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 5ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: CB, CE
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year

5V

1.2A

6W

65%

ErP II, CEC V,

UK
Wall
Type

SA106C-05AS

Input
Rated Voltage 100 - 240 VAC
Max. Voltage 90 - 264 VAC
Line Frequency 47 - 63 Hz
Current 250mA at 100-240VAC
Configuration Australia -2PIN
Output
Line Regulation Less than ±2%
Load Regulation Less than ±5%
Protections OCP, OVP & SCP
Ripple & Noise ≦100mVp-p, (For 5V, 9V models)
≦120mVp-p, (For 12V model)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
(primary - secondary)
Leakage Current: ≦0.25mA,at
264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.5 Watt
EMI: Complies with EMI directives
CEC Requirement: Standards for Power Supplies
Effective January 1, 2008
(Efficiency Level: IV)
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 90 ±5 g
DC Cord: 6ft


Environment
Operating Temp. 0℃- 40℃
Storage Temp. -20℃- 80℃
Humidity 10% - 90% (Non-condensing)
RoHS & WEEE Standard
   
Reliability
MTBF 50,000 hrs (MIL-217 Standard)
Safety ITE: CB
Others
Package 100 pcs/box
Min. Order 1K pcs/lot
Warranty 1 year

5V

1.2A

6W

65%

CEC IV

AUS  
Wall Type

SA106G-09BS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: British -2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 100 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
9V 0.67A 6W 70%

ErP II, CEC V

BRITISH WALL TYPE

SA106G-12BS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: British -2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 100 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
12V 0.5A 6W 70%

ErP II, CEC V

BRITISH WALL TYPE

SA106G-24BS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: British -2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 100 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
24V 0.25A 6W 70%

ErP II, CEC V

BRITISH WALL TYPE

SA106G-09GS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: Europe-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: TUV/GS, CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
9V 0.67A 6W 70%

ErP II, CEC V

EUROPEAN WALL TYPE

SA106G-12GS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: Europe-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: TUV/GS, CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
12V 0.5A 6W 70%

ErP II, CEC V

EUROPEAN WALL TYPE

SA106G-24GS

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: Europe-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
Efficiency Level: Stage 2
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: TUV/GS, CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
24V 0.25A 6W 70%

ErP II, CEC V

EUROPEAN WALL TYPE

SA106G-09S

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: UL-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement: EPS 2.0 (Efficiency Level V)
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: UL, cUL
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
9V 0.67A 6W 70%

CEC V

UL WALL TYPE

SA106G-12S

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: UL-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement: EPS 2.0 (Efficiency Level V)
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: UL, cUL
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
12V 0.5A 6W 70%

CEC V

UL WALL TYPE

SA106G-24S

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 300mA at 100-240VAC
Configuration: UL-2PIN
Output
Line Regulation: Less than ±5% ( 9V±7% )
Load Regulation: Less than ±5% ( 9V±7% )
Protections: OCP, OVP & SCP
Ripple & Noise: ≦120mVp-p, (For 9V, 12V)
                         ≦300mVp-p, (For 24V)
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/50Hz
Hold Up Time: ≧6 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement: EPS 2.0 (Efficiency Level V)
 
Mechanical
Case Size: 64L x 45W x 31H mm
Case Material: Black, 94V-1 or equivalent
Weight: 95 ±10 g
DC Cord: 4.92ft


Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: UL, cUL
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
24V 0.25A 6W 70%

CEC V

UL WALL TYPE

SA105k-05

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 150mA, at 100-240VAC
Configuration: UL-2PIN
Output
Line Regulation: Less than ±2%
Load Regulation: Less than ±5%
Protections: OCP, OVP & SCP
Ripple & Noise: ≦150mVp-p
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/60Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
Energy Star Requirement:
EPS 2.0 (Efficiency Level V) 
Mechanical
Case Size: 60L x 26W x 41H mm
Case Material: Black, 94V-1 or equivalent
Weight: 45 ±5 g
Output Connect: Standard-A Plug (USB)
                           (Without Output Cord)
Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: CE, CB
 
Others
Package: 100 pcs/box
Min. Order: 1K pcs/lot
Warranty: 1 year
 
5V 1.0A 5W 65%

SA105K-05G

Input
Rated Voltage: 100 - 240 VAC
Max. Voltage: 90 - 264 VAC
Line Frequency: 47 - 63 Hz
Current: 150mA, at 100-240VAC
Configuration: Europe-2PIN
Output
Line Regulation: Less than ±2%
Load Regulation: Less than ±5%
Protections: OCP, OVP & SCP
Ripple & Noise: ≦150mVp-p
   
Electrical
Topology: Switching Mode
Hi-Pot: 3000 Vac/1sec @ 5mA
           (primary - secondary)
Leakage Current: ≦0.25mA,at 264VAC/60Hz
Hold Up Time: ≧8 mSec
Standby Power: ≦0.3 Watt
EMI: Complies with EMI directives
EuP Requirement:
Efficiency Level: Stage 2
Mechanical
Case Size: 60L x 26W x 41H mm
Case Material: Black, 94V-1 or equivalent
Weight: 45 ±5 g
Output Connect: Standard-A Plug (USB)
                           (Without Output Cord)
Environment
Operating Temp.: 0℃- 40℃
Storage Temp.: -20℃- 80℃
Humidity: 10% - 90% (Non-condensing)
RoHS & WEEE: Standard
   
Reliability
MTBF: 50,000 hrs (by MIL-217 Standard)
Safety ITE: CE, CB
 
Others
Package: TBD
Min. Order: 1K pcs/lot
Warranty: 1 year
 
5V 1.0A 5W 65%
Add to Inquiry List
Review Inquiry List
Back